The standard frame is 32 timeslots, with each timeslot consisting of an 8-
bit byte. A MultiFrame consists of 16 frames, numbered 0 to 15.
The timeslots are numbered 0 to 31. Timeslot 0 is used for:
- Synchronization
- Alarm Transport
- International Carrier use
Timeslot 16 may be used to transmit Channel Associated Signaling (CAS)
- information. Note that G.732 DOES NOT define the signaling states, only
- The transport of the states through the G.732 frame.
However, G.704 recognizes the requirement for Common Channel
Signaling and also allows the TRANSPARENT End-To-End transport of
Timeslot 16.
Showing posts with label E1 Standards. Show all posts
Showing posts with label E1 Standards. Show all posts
Tuesday, August 28, 2007
E1 Standards
E1 standard (1)
The International CCITT framing format is adopted by most countries (Europe, Central/South America, etc.). These facilities operate at 2.048 MBPS.
This framing format is actually defined in CCITT
Recommendation G.704, although Recommendation G.732 supplements G.704.
G.704: Synchronous Frame Structure
- Used and Primary and Secondary
- Hierarchical Levels
G.732: Characteristics of Primary PCM
- Multiplex Equipment Operating at
- 2048 KBPS.
The International CCITT framing format is adopted by most countries (Europe, Central/South America, etc.). These facilities operate at 2.048 MBPS.
This framing format is actually defined in CCITT
Recommendation G.704, although Recommendation G.732 supplements G.704.
G.704: Synchronous Frame Structure
- Used and Primary and Secondary
- Hierarchical Levels
G.732: Characteristics of Primary PCM
- Multiplex Equipment Operating at
- 2048 KBPS.
Subscribe to:
Posts (Atom)